1 / 2
Vacuum hot water boiler
KDNV series in the small capacity type, KDNV series in the large capacity type
The KDNV vacuum hot water boiler encloses a fixed amount of heating medium water and keeps it in a vacuum (negative pressure) state in the boiler body. When the medium water is heated, it immediately evaporates into decompressed steam to indirectly heat the heat exchanger to provide hygienic water
Main specifications
Full specification table| Model | KDNV-10 ~ KDNV-300 · 19 models |
|---|---|
| Rated heat output | 0.12 – 3.49 MW (100,000 – 3,000,000 kcal/h) |
| Efficiency | 91% or more |
| Control method | ON - OFF · HI - LOW - OFF |
| Power | 220V x 1ø x 60Hz · 380V x 3ø x 60Hz |
Operating principle and features
-
Fuel cost reduction with high efficiency furnace design
The high efficiency body design, which adopts once-through characteristics of the water tube boiler, forms the water cooling wall structure and heat absorbing 3-pass structure, greatly reduces fuel costs.
-
Easy handling, no license and inspection required
Anyone can operate The KDNV vacuum hot water boiler as it is exempt from all laws and regulations in Korea (By law, the boiler is viewed as explosion-free boiler as it operates below atmospheric pressure). No license or inspection are required for operation.
-
Easy maintenance
Attaching the artificial intelligence D-Brain enables the easier operation and management. (Option)
-
Absolutely safe design
Unlike pressure boilers, the KDNV vacuum hot water boiler operates under negative pressure (pressure below atmospheric pressure) and has no risk of explosion. 4-level safety devices (Vacuum pressure, over heat prevention, boiler body thermistor and low water level switches) further ensures the reliability of the product.
-
Semi-permanent life
As the boiler water (heating medium water) of the vacuum hot water boiler is always kept in a fixed amount under vacuum condition without moving, there are no risks of corrosion or scale accumulation caused by dissolved oxygen. In addition with hygienic high corrosion resistant stainless steel heat exchangers, the boiler body is semi-permanent.
-
Multi-purpose heat exchangers
Heat exchangers can be used for heating, hot water supply and circulation heating in 1~3 circuits depending on the user’s demand. Each heat exchanger is independently installed and provides hygienic water without water mixing.
-
Low NOx Burner
Fuel cost can be saved by attaching a low NOx burner and 40ppm or less of NOx is guaranteed when operating under 4% of O2
Helium gas leak detector
Check any leakage after processing the boiler body → Check any leakage after assembling the heat exchanger→ Check any leakage after assembling the finished product
Standard specifications
KDNV series in the small capacity type, KDNV series in the large capacity typeStandard specifications for vacuum hot water boiler KDNV series
| Category | Unit | KDNV- 10 | KDNV- 15 | KDNV- 20 | KDNV- 25 | KDNV -30 | KDNV- 35 | KDNV- 40 | KDNV- 45 | KDNV- 50 | KDNV- 60 | KDNV- 80 | KDNV-100 | KDNV-120 | KDNV-130 | KDNV-150 | KDNV-160 | KDNV-200 | KDNV-250 | KDNV-300 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Boiler specifications | Rated heat output | MW | 0.12 | 0.17 | 0.23 | 0.29 | 0.35 | 0.41 | 0.47 | 0.52 | 0.58 | 0.70 | 0.93 | 1.16 | 1.40 | 1.51 | 1.74 | 1.86 | 2.33 | 2.91 | 3.49 |
| kcal/h | 100,000 | 150,000 | 200,000 | 250,000 | 300,000 | 350,000 | 400,000 | 450,000 | 500,000 | 600,000 | 800,000 | 1,000,000 | 1,200,000 | 1,300,000 | 1,500,000 | 1,600,000 | 2,000,000 | 2,500,000 | 3,000,000 | ||
| Efficiency | % | 91% or more | |||||||||||||||||||
| Heating area | ㎡ | 5.43 | 5.85 | 8.28 | 8.28 | 10.09 | 10.09 | 12.04 | 12.04 | 18 | 18 | 20 | 22 | 22 | 24 | 28 | 28 | 36 | 38 | 42 | |
| Control method | - | ON - OFF | HI - LOW - OFF | ||||||||||||||||||
| Total power consumption | kW | 0.3(0.25) | 0.3(0.35) | 0.47(0.47) | 0.47(0.47) | 0.84(0.84) | 1.2(1.2) | 1.6(1.2) | 2.3(1.9) | 2.3(3.1) | 4.1(3.1) | 4.1(7.6) | 11(7.6) | 15(7.6) | 18.5(11.1) | ||||||
| Power | V | 220V x 1ø x 60Hz | 380V x 3ø x 60Hz | ||||||||||||||||||
| Retained heating medium water volume | L | 200 | 220 | 300 | 330 | 390 | 400 | 470 | 480 | 500 | 550 | 650 | 700 | 750 | 790 | 830 | 900 | 1,300 | 1,600 | 1,900 | |
| Fuel consumption | LNG | N㎥/h | 11.0 | 16.5 | 22.0 | 27.5 | 33.0 | 38.5 | 44.0 | 49.5 | 54.9 | 65.9 | 87.9 | 109.9 | 131.9 | 142.9 | 164.8 | 175.8 | 219.8 | 274.7 | 329.7 |
| Propane(LPG) | 4.9 | 7.4 | 9.8 | 12.3 | 14.7 | 17.2 | 19.6 | 22.1 | 24.5 | 29.4 | 39.2 | 49.1 | 58.9 | 63.8 | 73.6 | 78.5 | 98.1 | 122.6 | 147.2 | ||
| Butane | 3.7 | 5.6 | 7.5 | 9.3 | 11.2 | 13.0 | 14.9 | 16.8 | 18.6 | 22.4 | 29.8 | 37.3 | 44.7 | 48.4 | 55.9 | 59.6 | 74.5 | 93.1 | 111.8 | ||
| Diesel | kg/h | 10.7 | 16.0 | 21.3 | 26.7 | 32.0 | 37.3 | 42.7 | 48.0 | 53.3 | 64.0 | 85.4 | 106.7 | 128.0 | 138.7 | 160.0 | 170.7 | 213.4 | 266.7 | 320.1 | |
| Connection diameter | Oil inlet | A | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 |
| Gas inlet | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 65 | 65 | ||
| Flue | ømm | 200 | 200 | 200 | 200 | 250 | 250 | 250 | 250 | 300 | 300 | 350 | 350 | 350 | 400 | 400 | 400 | 500 | 550 | 600 | |
| Base size | Width(W) | mm | 1,060 | 1,060 | 1,200 | 1,200 | 1,300 | 1,300 | 1,450 | 1,450 | 1,140 | 1,140 | 1,440 | 1,510 | 1,510 | 1,510 | 1,530 | 1,530 | 1,790 | 2,100 | 3,100 |
| Length(L) | 1,060 | 1,060 | 1,200 | 1,200 | 1,300 | 1,300 | 1,450 | 1,450 | 2,500 | 2,730 | 2,260 | 2,260 | 2,260 | 2,260 | 2,560 | 2,560 | 2,870 | 3,400 | 3,800 | ||
| Height(H) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | ||
| External size (Gas) | Width(W) | mm | 860 | 860 | 1,000 | 1,000 | 1,100 | 1,100 | 1,250 | 1,250 | 1,140 | 1,140 | 1,440 | 1,510 | 1,510 | 1,510 | 1,530 | 1,530 | 1,890 | 2,000 | 2,180 |
| Length(L) | 1,370 | 1,370 | 1,640 | 1,640 | 1,740 | 1,810 | 2,000 | 2,000 | 3,270 | 3,570 | 3,610 | 3,640 | 3,640 | 3,690 | 3,960 | 3,960 | 4,730 | 5,120 | 5,280 | ||
| Height(H) | 1,640 | 1,640 | 1,870 | 1,870 | 1,900 | 1,900 | 1,920 | 1,920 | 1,570 | 1,570 | 2,170 | 2,340 | 2,340 | 2,340 | 2,530 | 2,530 | 2,580 | 2,720 | 2,860 | ||
| External size (Diesel) | Width(W) | mm | 860 | 860 | 1,000 | 1,000 | 1,100 | 1,100 | 1,250 | 1,250 | 1,140 | 1,140 | 1,440 | 1,510 | 1,510 | 1,510 | 1,530 | 1,530 | 1,890 | ||
| Length(L) | 1,350 | 1,350 | 1,530 | 1,530 | 1,630 | 1,730 | 1,940 | 1,940 | 3,150 | 3,390 | 3,230 | 3,370 | 3,370 | 3,420 | 3,710 | 3,710 | 4,510 | ||||
| Height(H) | 1,640 | 1,640 | 1,870 | 1,870 | 1,900 | 1,900 | 1,920 | 1,920 | 1,570 | 1,570 | 2,170 | 2,340 | 2,340 | 2,340 | 2,530 | 2,530 | 2,580 | ||||
| Product weight | kg | 500 | 520 | 700 | 720 | 870 | 900 | 1,100 | 1,150 | 1,250 | 1,900 | 2,750 | 3,320 | 3,500 | 3,820 | 4,250 | 4,500 | 5,200 | 5,650 | 6,800 | |
The external size may vary depending on the control panel and burner specifications.
Specifications in ( ) are diesel boiler specifications.
For heating and hot water circulation (333K → 343K) {60℃ → 70℃}
| Category | Unit | KDNV -10 | KDNV -15 | KDNV -20 | KDNV -25 | KDNV -30 | KDNV -35 | KDNV -40 | KDNV -45 | KDNV -50 | KDNV -60 | KDNV -80 | KDNV -100 | KDNV -120 | KDNV -130 | KDNV -150 | KDNV -160 | KDNV -200 | KDNV -250 | KDNV -300 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For heating and hot water circulation | Rated heat output | MW | 0.12 | 0.17 | 0.23 | 0.28 | 0.35 | 0.41 | 0.47 | 0.52 | 0.58 | 0.7 | 0.93 | 1.16 | 1.40 | 1.51 | 1.74 | 1.86 | 2.33 | 2.01 | 3.49 |
| kcal/h | 100,000 | 150,000 | 200,000 | 250,000 | 300,000 | 350,000 | 400,000 | 450,000 | 500,000 | 600,000 | 800,000 | 1,000,000 | 1,200,000 | 1,300,000 | 1,500,000 | 1,600,000 | 2,000,000 | 2,500,000 | 3,000,000 | ||
| Circulation volume | ℓ | 10,000 | 15,000 | 20,000 | 25,000 | 30,000 | 35,000 | 40,000 | 45,000 | 50,000 | 60,000 | 80,000 | 100,000 | 120,000 | 130,000 | 150,000 | 160,000 | 200,000 | 250,000 | 300,000 | |
| Maximum operating pressure | MPa{kgf/㎠} | 1{10} | |||||||||||||||||||
| Pressure loss | MPa{mH2O} | 0.012{0.12} | 0.017{0.17} | 0.02{0.2} | 0.018{0.18} | 0.022{0.22} | 0.03{0.3} | 0.033{0.33} | 0.022{0.22} | 0.03{0.3} | 0.033{0.33} | 0.035{0.35} | 0.04{0.4} | ||||||||
| Material | - | Stainless steel pipe | |||||||||||||||||||
| Connection diameter | A | 40 | 40 | 50 | 50 | 50 | 50 | 65 | 65 | 80 | 80 | 80 | 100 | 100 | 100 | 100 | 100 | 150 | 150 | 150 | |
For hot water supply (298K → 338K) {25℃ → 65℃}
| Category | Unit | KDNV -10 | KDNV -15 | KDNV -20 | KDNV -25 | KDNV -30 | KDNV -35 | KDNV -40 | KDNV -45 | KDNV -50 | KDNV -60 | KDNV -80 | KDNV -100 | KDNV -120 | KDNV -130 | KDNV -150 | KDNV -160 | KDNV -200 | KDNV -250 | KDNV -300 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For hot water supply | Rated heat output | MW | 0.12 | 0.17 | 0.23 | 0.28 | 0.35 | 0.41 | 0.47 | 0.52 | 0.58 | 0.7 | 0.93 | 1.16 | 1.40 | 1.51 | 1.74 | 1.86 | 2.33 | 2.01 | 3.49 |
| kcal/h | 100,000 | 150,000 | 200,000 | 250,000 | 300,000 | 350,000 | 400,000 | 450,000 | 500,000 | 600,000 | 800,000 | 1,000,000 | 1,200,000 | 1,300,000 | 1,500,000 | 1,600,000 | 2,000,000 | 2,500,000 | 3,000,000 | ||
| Circulation volume | ℓ | 2,500 | 3,750 | 5,000 | 6,250 | 7,500 | 8,750 | 10,000 | 11,250 | 12,500 | 15,000 | 20,000 | 25,000 | 30,000 | 32,500 | 40,000 | 40,000 | 40,000 | 62,500 | 75,000 | |
| Maximum operating pressure | MPa{kgf/㎠} | 1{10} | |||||||||||||||||||
| Pressure loss | MPa{mH2O} | 0.06{0.06} | 0.015{0.15} | 0.018{0.18} | 0.015{0.15} | 0.02{0.2} | 0.024{0.24} | 0.033{0.33} | 0.022{0.22} | 0.03{0.3} | 0.022{0.22} | 0.035{0.35} | 0.04{0.4} | ||||||||
| Material | - | Stainless steel pipe | |||||||||||||||||||
| Connection diameter | A | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | 65 | 65 | 65 | 80 | 80 | 80 | 100 | 100 | |
For hot water supply (278K → 338K) {5℃ → 65℃}
| Category | Unit | KDNV -10 | KDNV -15 | KDNV -20 | KDNV -25 | KDNV -30 | KDNV -35 | KDNV -40 | KDNV -45 | KDNV -50 | KDNV -60 | KDNV -80 | KDNV -100 | KDNV -120 | KDNV -130 | KDNV -150 | KDNV -160 | KDNV -200 | KDNV -250 | KDNV -300 | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For hot water supply | Rated heat output | MW | 0.12 | 0.17 | 0.23 | 0.28 | 0.35 | 0.41 | 0.47 | 0.52 | 0.58 | 0.7 | 0.93 | 1.16 | 1.40 | 1.51 | 1.74 | 1.86 | 2.33 | 2.01 | 3.49 |
| kcal/h | 100,000 | 150,000 | 200,000 | 250,000 | 300,000 | 350,000 | 400,000 | 450,000 | 500,000 | 600,000 | 800,000 | 1,000,000 | 1,200,000 | 1,300,000 | 1,500,000 | 1,600,000 | 2,000,000 | 2,500,000 | 3,000,000 | ||
| Circulation volume | ℓ | 1,667 | 2,500 | 3,333 | 4,167 | 5,000 | 5,833 | 6,667 | 7,500 | 8,333 | 10,000 | 13,333 | 16,667 | 20,000 | 21,667 | 25,000 | 26,667 | 33,333 | 41,667 | 50,000 | |
| Maximum operating pressure | MPa{kgf/㎠} | 1{10} | |||||||||||||||||||
| Pressure loss | MPa{mH2O} | 0.06{0.06} | 0.015{0.15} | 0.018{0.18} | 0.015{0.15} | 0.02{0.2} | 0.024{0.24} | 0.033{0.33} | 0.022{0.22} | 0.03{0.3} | 0.022{0.22} | 0.035{0.35} | 0.04{0.4} | ||||||||
| Material | - | Stainless steel pipe | |||||||||||||||||||
| Connection diameter | A | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | 65 | 65 | 65 | 80 | 80 | 80 | 100 | 100 | |
The above specification table is indicated as follows.
- The fuel calorific value of fuel consumption is based on the low-level calorific value.
- LNG : 10,000 kcal/N㎥
- LPG(Propane) : 22,400 kcal/N㎥
- LPG(Butane) : 29,500 kcal/N㎥
- Diesel:10,300 kcal/kg(gravity:0.836)
Design flow temperature condition for heating and hot water circulation 333~343K {60~70℃}
Design flow temperature condition for hot water supply 298~338K {25~65℃}, 278~338K {5~65℃}
The rated heat output for heating and hot water supply is given for each individual use, and in the case of simultaneous use, the total is the boiler heat output.
The following tolerances are included due to the measurement errors of the measuring instrument or measuring personnel.
- Boiler efficiency measurement error ±1%
The above boiler efficiency is based on the true heat generation (low heat generation).
The above specification table is subject to change without notice.
This specification is based on a gas boiler. For detailed specifications, refer to the specification table.
Consultation and quotes
Tell us where the boiler will be installed and what it is for.
Our engineers will get back to you.