Condensing high efficiency once-through steam boiler

KDKE-HE Series

Main specifications

Full specification table
ModelKDKE-400HE ~ KDKE-4000HE · 9 models
Rated evaporation400 – 4,000 kg/h
Efficiency99%
Control methodHI - LOW - OFF
Power consumption2.35 – 22.3 kw

Feature

  • Equipped with a high-performance water supply pre-heater (STS-304/316), it absorbs the high-temperature exhaust gas’s heat generated after combustion as much as possible, and increases the water inlet temperature to achieve more than 99% efficiency.

  • As the conductivity of boiler water is maintained within the allowable value by automatically measuring the concentration of boiler water, there is no carry-over and the lifespan is extended.

  • Compact body design reduces the volume of retained water and allows steam to be generated quickly within 3~5 minutes after burner ignition.

  • Easy to handle as operation, water supply and burner combustion control can be automatically controlled and set with one-touch operation

  • Equipped with a high-performance steam separator to supply high-quality dry steam even with sudden load fluctuations.

  • Attaching a low-NOx burner ensures fuel cost saving, and NOx of 40 ppm or less is guaranteed for operation under 4% of O₂. (Option)

  • The artificial intelligence D-Brain control enables easier operation and management. (Option)

Integrated boiler control system

Cascade unit control system can minimize installation space and enhance response to load fluctuation.

Condensing high efficiency once-through steam boiler Integrated boiler control system figure
Condensing high efficiency once-through steam boiler Integrated boiler control system figure

Standard specifications

KDKE-HE Series

Standard specifications for condensing high efficiency once-through type of steam boiler KDKE-HE series

Category Unit KDKE-400HE KDKE-500HE KDKE-800HE KDKE-1000HE KDKE-1500HE KDKE-2000HE KDKE-2500HE KDKE-3000HE KDKE-4000HE
Boiler specifications Rated evaporation kg/h 400 500 800 1,000 1,500 2,000 2,500 3,000 4,000
Heat output MW 0.30 0.37 0.60 0.75 1.12 1.50 1.87 2.25 2.99
kcal/h 257.480 321,850 514,960 643,700 965,550 1,287,400 1,609,250 1,931,100 2,574,800
Efficiency % 99%
Heating area ㎡ 4.9 4.99 9.5 9.7 9.99 20.00 22 23 29
Control method - HI - LOW - OFF
Power V 220V x 3ø x 60Hz / 380V x 3ø x 60Hz
Fuel consumption LNG N㎥/h 26.01 32.51 52.02 65.02 97.53 130.04 162.55 195.06 260.08
Propane N㎥/h 11.61 14.51 23.22 29.03 43.54 58.05 72.57 87.08 116.11
Butane N㎥/h 8.88 11.02 17.63 22.04 33.06 44.08 55.10 66.12 88.16
Diesel kg/h - - - - - - - - -
Power consumption Total electric capacity kW 2.35 2.35 6.0 6.0 9.8 14.8 14.8 18.8 22.3
Blower motor 0.75 0.75 3.70 3.70 7.5 11.0 11.0 15.0 18.5
Water pump 1.5 1.5 2.2 2.2 2.2 3.4 3.4 3.7 3.7
Connection diameter Steam outlet A 40 40 50 50 65 80 80 80 100
Water inlet 25 25 25 25 25 40 40 40 50
Drainage outlet 25 25 25 25 25 25 25 25 25
Gas inlet 40 40 40 40 50 50 50 50 50
Flue ø mm 250 250 300 300 350 400 500 500 500
External size Width(W) mm 1,000 1,000 1,550 1,600 1,650 2,450 2,460 2,510 2,560
Length(L) 1,900 1,900 2,100 2,150 2,550 3,050 3,050 2,750 2,750
Height(H) 2,160 2,160 2,450 2,650 2,700 3,130 3,230 3,290 3,730
Weight kg 1,100 1,240 1,710 2,000 2,300 4,400 5,200 6,300 7,200

The qualified evaporation amount is based on the water supply temperature of 20℃ and steam pressure of 1MPa.
Fuel consumption is based on the low-level calorific value.
Low-level calorific value ① LNG : 10,000 kcal/N㎥ ② Propane : 22,400 kcal/N㎥ ③ Butane : 10,000 kcal/N㎥ ④ Diesel : 10,000 kcal/N㎥ (Low-level calorific value, specific gravity 0.836)
These specifications are subject to change without prior notice to improve product performance.
This specification is based on a gas boiler. For detailed specifications, refer to the specification table.

Consultation and quotes

Tell us where the boiler will be installed and what it is for.
Our engineers will get back to you.