Condensing high efficiency once-through steam boiler
KDKE-HE Series
Main specifications
Full specification table| Model | KDKE-400HE ~ KDKE-4000HE · 9 models |
|---|---|
| Rated evaporation | 400 – 4,000 kg/h |
| Efficiency | 99% |
| Control method | HI - LOW - OFF |
| Power consumption | 2.35 – 22.3 kw |
Feature
-
Equipped with a high-performance water supply pre-heater (STS-304/316), it absorbs the high-temperature exhaust gas’s heat generated after combustion as much as possible, and increases the water inlet temperature to achieve more than 99% efficiency.
-
As the conductivity of boiler water is maintained within the allowable value by automatically measuring the concentration of boiler water, there is no carry-over and the lifespan is extended.
-
Compact body design reduces the volume of retained water and allows steam to be generated quickly within 3~5 minutes after burner ignition.
-
Easy to handle as operation, water supply and burner combustion control can be automatically controlled and set with one-touch operation
-
Equipped with a high-performance steam separator to supply high-quality dry steam even with sudden load fluctuations.
-
Attaching a low-NOx burner ensures fuel cost saving, and NOx of 40 ppm or less is guaranteed for operation under 4% of O₂. (Option)
-
The artificial intelligence D-Brain control enables easier operation and management. (Option)
Integrated boiler control system
Cascade unit control system can minimize installation space and enhance response to load fluctuation.
Standard specifications
KDKE-HE SeriesStandard specifications for condensing high efficiency once-through type of steam boiler KDKE-HE series
| Category | Unit | KDKE-400HE | KDKE-500HE | KDKE-800HE | KDKE-1000HE | KDKE-1500HE | KDKE-2000HE | KDKE-2500HE | KDKE-3000HE | KDKE-4000HE | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Boiler specifications | Rated evaporation | kg/h | 400 | 500 | 800 | 1,000 | 1,500 | 2,000 | 2,500 | 3,000 | 4,000 |
| Heat output | MW | 0.30 | 0.37 | 0.60 | 0.75 | 1.12 | 1.50 | 1.87 | 2.25 | 2.99 | |
| kcal/h | 257.480 | 321,850 | 514,960 | 643,700 | 965,550 | 1,287,400 | 1,609,250 | 1,931,100 | 2,574,800 | ||
| Efficiency | % | 99% | |||||||||
| Heating area | ㎡ | 4.9 | 4.99 | 9.5 | 9.7 | 9.99 | 20.00 | 22 | 23 | 29 | |
| Control method | - | HI - LOW - OFF | |||||||||
| Power | V | 220V x 3ø x 60Hz / 380V x 3ø x 60Hz | |||||||||
| Fuel consumption | LNG | N㎥/h | 26.01 | 32.51 | 52.02 | 65.02 | 97.53 | 130.04 | 162.55 | 195.06 | 260.08 |
| Propane | N㎥/h | 11.61 | 14.51 | 23.22 | 29.03 | 43.54 | 58.05 | 72.57 | 87.08 | 116.11 | |
| Butane | N㎥/h | 8.88 | 11.02 | 17.63 | 22.04 | 33.06 | 44.08 | 55.10 | 66.12 | 88.16 | |
| Diesel | kg/h | - | - | - | - | - | - | - | - | - | |
| Power consumption | Total electric capacity | kW | 2.35 | 2.35 | 6.0 | 6.0 | 9.8 | 14.8 | 14.8 | 18.8 | 22.3 |
| Blower motor | 0.75 | 0.75 | 3.70 | 3.70 | 7.5 | 11.0 | 11.0 | 15.0 | 18.5 | ||
| Water pump | 1.5 | 1.5 | 2.2 | 2.2 | 2.2 | 3.4 | 3.4 | 3.7 | 3.7 | ||
| Connection diameter | Steam outlet | A | 40 | 40 | 50 | 50 | 65 | 80 | 80 | 80 | 100 |
| Water inlet | 25 | 25 | 25 | 25 | 25 | 40 | 40 | 40 | 50 | ||
| Drainage outlet | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | ||
| Gas inlet | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | ||
| Flue | ø mm | 250 | 250 | 300 | 300 | 350 | 400 | 500 | 500 | 500 | |
| External size | Width(W) | mm | 1,000 | 1,000 | 1,550 | 1,600 | 1,650 | 2,450 | 2,460 | 2,510 | 2,560 |
| Length(L) | 1,900 | 1,900 | 2,100 | 2,150 | 2,550 | 3,050 | 3,050 | 2,750 | 2,750 | ||
| Height(H) | 2,160 | 2,160 | 2,450 | 2,650 | 2,700 | 3,130 | 3,230 | 3,290 | 3,730 | ||
| Weight | kg | 1,100 | 1,240 | 1,710 | 2,000 | 2,300 | 4,400 | 5,200 | 6,300 | 7,200 | |
The qualified evaporation amount is based on the water supply temperature of 20℃ and steam pressure of 1MPa.
Fuel consumption is based on the low-level calorific value.
Low-level calorific value ① LNG : 10,000 kcal/N㎥ ② Propane : 22,400 kcal/N㎥ ③ Butane : 10,000 kcal/N㎥ ④ Diesel : 10,000 kcal/N㎥ (Low-level calorific value, specific gravity 0.836)
These specifications are subject to change without prior notice to improve product performance.
This specification is based on a gas boiler. For detailed specifications, refer to the specification table.
Consultation and quotes
Tell us where the boiler will be installed and what it is for.
Our engineers will get back to you.