Two circuit flue and smoke tube hot water boiler

SUPER series

It is a high-performance, high efficiency boiler that has unique 3-pass combustion structure and eccentric corrugated combustion chamber that facilitates hot water circulation inside the boiler body and greatly increases the heat exchanger heat absorption.

Main specifications

Full specification table
ModelSUPER-30 ~ SUPER-100 · 6 models
Rated heat output0.35 – 1.16 MW (300,000 – 1,000,000 kcal/h)
Efficiency88%

Feature

  • Both hot water and heating can be solved at the same time with one boiler.

  • Scale generation and dissolved oxygen corrosion are reduced by attaching the heat exchanger to the inside of the boiler.

  • Smoking chamber has no risk of collapse as it is made with fire-resistant bricks and is made as water-room type to maximize heating surface.

  • The heating surface of the heat exchanger, which is the life of a hot water boiler, is expanded as much as possibly by designing the copper pipe installation of the heat exchanger with the largest capacity in Korea (Containing 8-10% more than the actual required amount).

Standard specifications

SUPER series

Standard specifications for the flue and smoke tube type of hot water boiler

Category Unit Standard specifications for flue and smoke tube 2-circuit type of SUPER series
SUPER - 30 SUPER - 40 SUPER - 50 SUPER - 60 SUPER - 80 SUPER - 100
Boiler body Rated heat output MW 0.35 0.47 0.58 0.7 0.93 1.16
kcal/h 300,000 400,000 500,000 600,000 800,000 1,000,000
Maximum operating pressure Mpa[㎏/㎠] 0.35 [3.5] 0.35 [3.5], 0.7 [7], 1.0 [10] (Optional)
Efficiency % 88%
Operating power V 220V x 3ø x 60Hz / 380V x 3ø x 60Hz x 4W
Burner output kW 0.3(0.25) 0.3(0.35) 0.47(0.47) 2.2 2.2 0.7
Fuel consumption Boiler kerosene kg/h 39.8 53 66.3 79.5 106 132.5
Heavy oil 36.7 49.1 61.3 73.6 98.1 122.6
LNG N㎥/h 34.1 45.4 56.8 68.2 90.9 113.6
Propane 15.2 20.3 25.4 30.4 40.6 50.7
LPG+AIR 24.7 32.9 41.1 49.4 65.8 82.3
Connection diameter Heating Inlet and Outlet A 80 100 100 125 125 150
Heating Inlet and Outlet 50 50 50 50 65 65
Drainage valve 32 32 32 40 50 50
Flue ø 250 300 300 300 350 400
External size Width(W) mm 1,440 1,500 1,500 1,500 1,680 1,720
Length(L) 2,100 2,300 2,460 2,620 2,830 3,060
Height(H) 1,690 1,780 1,780 1,920 2,150 2,270

Fuel consumption in the above specification table is based on the following..
- Low-level calorific value
① Boiler kerosene : 44,116kJ/kg{10,300kcal/kg}
② Heavy oil : 40,813kJ/kg{9,750kcal/kg}
③ LNG : 41.9KJ/N㎥{10,000kcal/N㎥}
④ Propane : 93.8KJ/N㎥{22,400kcal/N㎥}
⑤ LPG+AIR : 57.8KJ/N㎥{13,800kcal/N㎥}