Z-MINI flue and smoke tube steam boiler

Z-MINI Series

Main specifications

Full specification table
ModelZ-MINI-50 ~ Z-MINI-1000 · 10 models
Rated evaporation500 – 10,000 kg/h
Maximum operating pressure1 [10] Mpa[㎏/㎠]
Efficiency88%
Power consumption5 – 20 kW

Feature

  • 3-pass structure

  • High efficiency by using the special spiral flue.

  • Easy to replace and repair the flue with handy open-close smoke room door design.

  • Easy to clean, inspect and maintain.

  • Steam generation is fast (dry steam is generated 6-10 minutes after ignition) and thermal efficiency is high as the retained water of the boiler is small.

  • Requires only 1/2 installation space compare to existing boilers of the same capacity.

  • Attaching the artificial intelligence controller D-Brain enables the easier operation and management. (Optional)

Standard specifications

Z-MINI Series

Standard specifications for flue and smoke tube type of steam boiler

Category Unit Z-MINI series in the ultra-small capacity
Z-MINI - 50 Z-MINI - 80 Z-MINI - 100 Z-MINI - 150 Z-MINI - 200 Z-MINI - 250 Z-MINI - 300 Z-MINI - 500 Z-MINI - 800 Z-MINI - 1000
Boiler specifications Rated evaporation kg/h 500 800 1,000 1,500 2,000 2,500 3,000 5,000 8,000 10,000
Maximum operating pressure Mpa[㎏/㎠] 1 [10]
Heat output MW 0.38 0.6 0.75 1.12 1.5 1.87 2.25 3.74 5.99 7.49
kcal/h 321,850 514,960 643,700 965,550 1,287,400 1,609,250 1,931,100 3,218,500 5,149,600 6,437,000
Efficiency % 88%
Weight kg 2,250 2,410 2,500 2,650 2,900 3,410 3,550 4,310 5,620 7,020
Operating power V 220V × 3ø x 60Hz / 380V × 3ø x 60Hz × 4W
Combustion method - Forced mixing type
Control method - High - Low - Off / Fully Automatic
Retaining quantity kg 800 850 920 980 1,050 1,410 1,520 1,850 2,310 2,650
Fuel consumption Boiler kerosene kg/h 41.7 66.7 83.5 125.3 167.1 208.9 250.6 417.6 668.6 835.7
Heavy oil 38.5 61.7 77.1 115.7 154.2 192.7 231.4 385.6 617.1 771.3
LNG N㎥/h 36.6 58.5 73.1 109.7 146.3 182.9 219.4 365.7 585.2 731.5
Propane 16.3 26.1 32.7 49.0 65.3 81.6 98.0 163.3 261.2 326.6
LPG+AIR 25.8 41.4 51.7 77.6 103.5 129.4 155.3 258.8 414.1 517.7
Power consumption Water pump kW 1.5X2 1.5X2 2.2X2 2.2X2 2.2X2 2.2X2 3.7X2 3.7X2 5X2 5X2
Oil heater 5 5 6 6 9 9 10 16 20 20
Oil pump 0.4 0.4 0.4 0.4 0.75 0.75 0.75 2.2 3.7 3.7
Burner motor 1.5 2.2 2.2 3.7 5.5 7.5 7.5 15.0 19.0 22.0
Connection diameter Main steam valve A 40 50 50 65 80 80 80 125 150 200
Safety valve 25 25 25 32 40 40 40 40,40 40,50 50,50
Water supply valve 25 25 25 25 40 40 40 40 50 50
Drainage valve
Water supply inlet 15 15 15 20 20 25 25 32 40 40
Gas inlet 40 50 50 50 50 50 50 50 80 100
Exhaust outlet ø mm 250X350 300X380 300X400 300X440 350X500 400X550 400X580 450X600 500X700 550X800
Flue
External size Width(W) mm 1,550 1,850 1,850 1,900 1,970 2,070 2,150 2,300 2,550 2,800
Length(L) 2,850 3,600 3,800 4,000 4,450 4,900 5,050 5,350 5,600 5,950
Height(H) 2,050 2,400 2,400 2,450 2,580 2,680 2,800 3,050 3,250 3,450

Fuel consumption is based on the low-level calorific value.
- Low-level calorific value
① Boiler kerosene : 43,116kJ/kg{10,300kcal/kg}
② Heavy oil : 40,813kJ/kg{9,750kcal/kg}
③ LNG : 41.9KJ/N㎥{10,000kcal/N㎥}
④ Propane : 93.8KJ/N㎥{22,400kcal/N㎥}
⑤ LPG+AIR : 57.8KJ/N㎥{13,800kcal/N㎥}
The rated evaporation amount is based on the water supply temperature of 20℃, steam pressure of 0.35Mpa {3.5kg/㎠} and 1Mpa {10kg/㎠}.
The efficiency measurement of the boiler is based on the low-level calorific value of the fuel and the value at the time of rating.
These specifications are subject to change without prior notice to improve product performance.