1 / 2
Premium instant boiler
KDNV-G2PHEX
Among hot water boilers
- 93.5% Highest efficiency
- 10 ppm Ultra-low NOx
It stably supplies large volumes of hot water to large-scale facilities while meeting hot water demand without a storage tank. Fully proportional control and Korea’s first modular hot water boiler control system provide efficient operation across the entire load range. This tankless hot water system reduces the installation area by 70% compared with conventional hot water systems and lowers maintenance costs by eliminating hot water storage tanks. The indirect-heating boiler design is exempt from licensing and inspection requirements, reducing incidental costs such as inspection, water treatment, and chemical dosing. Our high-performance heat exchanger is designed for smooth hot water flow, preventing scale and foreign-material buildup and maintaining its initial efficiency for more than 10 years.
Main specifications
Full specification table| Model | KDNV-20G2MHEX ~ KDNV-37G2MHEX · 8 models |
|---|---|
| Rated heat output | 0.23 – 0.43 MW (200,000 – 370,000 kcal/h) |
| Efficiency | 99% or Higher (Based on Lower Heating Value) |
| Control method | Inverter Proportional Control |
| Power consumption | 1.3 kW |
| Power | 220V x 1ø |
3-NO Product
How it works and features
-
Tankless hot water supply system
(Tankless system)
-
70% less installation space
Compared with conventional hot water systems
-
No-license, no-inspection products
reduce incidental costs such as inspection and customs fees
-
Reduced maintenance costs
By simplifying auxiliary facilities
-
Korea’s highest efficiency: 93%
(Based on higher heating value)
-
Specially designed high-performance heat exchanger
provides excellent resistance to scale buildup
-
Fully proportional control
operation
-
Hot water at an average temperature of 65℃ to 70℃ the risk of infection
reduces Legionella concentration and the likelihood of exposure, lowering
PREMIX BURNER
Premixed Combustion
- 1No separate combustion chamber is required due to the surface combustion method.
- 2Fully proportional control operation (15:1)
- 3The premixed combustion method eliminates furnace explosions associated with forced-mixing systems.
- 4Ultra-low NOx emissions across the full load range (20 ppm or less)
D-BRAIN (MODULAR SYSTEM)
Developed from 50 years of hot water boiler manufacturing expertise, Korea’s first D-BRAIN modular control system senses load flow and average flow temperatures and optimally controls the number of boilers in operation, helping reduce energy consumption.
- 1(For installations of 3 or more boilers // up to 16 boilers)
Standard specifications
KDNV-G2PHEXSTANDARD SPECIFICATIONS
| Category | Type | Unit | KDNV- 20G2MHEX | KDNV- 23G2MHEX | KDNV- 24G2MHEX | KDNV- 25G2MHEX | KDNV- 30G2MHEX | KDNV- 31G2MHEX | KDNV- 35G2MHEX | KDNV- 37G2MHEX |
|---|---|---|---|---|---|---|---|---|---|---|
| Boiler Specifications | Rated Heat Output | MW | 0.23 | 0.28 | 0.28 | 0.29 | 0.35 | 0.36 | 0.41 | 0.43 |
| kcal/h | 200,000 | 237,000 | 240,800 | 250,000 | 300,000 | 307,000 | 350,000 | 370,000 | ||
| Efficiency | % | 99% or Higher (Based on Lower Heating Value) | ||||||||
| Heat Transfer Area | m² | 7.1 | 7.1 | 7.1 | 7.1 | 7.1 | 8.0 | 8.0 | 8.0 | |
| Burner | - | DP2 | DP3 | |||||||
| Burner Capacity | kcal/h | 60,000 ~ 300,000 | 90,000 ~ 450,000 | |||||||
| Control Method | - | Inverter Proportional Control | ||||||||
| Blower Capacity | kW | 1.2 | ||||||||
| Total Power Consumption | kW | 1.3 | ||||||||
| Power Supply | V | 220V x 1ø | ||||||||
| Product Weight | kg | 1,100 | 1,110 | 1,120 | 1,120 | 1,130 | 1,210 | 1,220 | 1,230 | |
| Fuel Consumption | LNG | N㎥/h | 20.2 | 23.9 | 24.3 | 25.3 | 30.3 | 31.0 | 35.4 | 37.4 |
| Propane (LPG) | N㎥/h | 9.0 | 10.7 | 10.9 | 11.3 | 13.5 | 13.8 | 15.8 | 16.7 | |
| Connection Size | Gas Inlet | A | 25 | 40 | ||||||
| Flue | ømm | 200 | 200 | 200 | 200 | 250 | 250 | 250 | 250 | |
| Overall Dimensions | Width (W) | mm | 1,050 | 1,050 | 1,050 | 1,050 | 1,050 | 1,050 | 1,050 | 1,050 |
| Length (L) | 2,250 | 2,650 | 2,650 | 2,650 | 2,690 | 2,870 | 2,870 | 2,900 | ||
| Height (H) | 1,780 | 1,780 | 1,780 | 1,780 | 1,780 | 1,780 | 1,780 | 1,780 | ||
Heating & Hot Water Circulation (333K → 343K) {60℃ → 70℃}
| Category | Type | Unit | KDNV- 20G2MHEX | KDNV- 23G2MHEX | KDNV- 24G2MHEX | KDNV- 25G2MHEX | KDNV- 30G2MHEX | KDNV- 31G2MHEX | KDNV- 35G2MHEX | KDNV- 37G2MHEX |
|---|---|---|---|---|---|---|---|---|---|---|
| Heating and Hot Water Circulation | Rated Heat Output | MW | 0.23 | 0.28 | 0.28 | 0.29 | 0.35 | 0.36 | 0.41 | 0.43 |
| kcal/h | 200,000 | 237,000 | 240,800 | 250,000 | 300,000 | 307,000 | 350,000 | 370,000 | ||
| Circulation Flow Rate | ℓ | 20,000 | 23,700 | 24,080 | 25,000 | 30,000 | 30,700 | 35,000 | 37,000 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | ||||||||
| Head Loss | MPa{mH₂O} | 0.015{1.5} | 0.021{2.1} | 0.021{2.1} | 0.023{2.3} | 0.02{2.0} | 0.021{2.1} | 0.027{2.7} | 0.03{3.0} | |
| Material | - | Stainless Steel Pipe | ||||||||
| Connection Size | A | 50 | 50 | 50 | 50 | 65 | 65 | 65 | 65 | |
Heating & Hot Water Circulation (333K → 343K) {50℃ → 70℃}
| Category | Type | Unit | KDNV- 20G2MHEX | KDNV- 23G2MHEX | KDNV- 24G2MHEX | KDNV- 25G2MHEX | KDNV- 30G2MHEX | KDNV- 31G2MHEX | KDNV- 35G2MHEX | KDNV- 37G2MHEX |
|---|---|---|---|---|---|---|---|---|---|---|
| Hot Water Supply | Rated Heat Output | MW | 0.23 | 0.28 | 0.28 | 0.29 | 0.35 | 0.36 | 0.41 | 0.43 |
| kcal/h | 200,000 | 237,000 | 240,800 | 250,000 | 300,000 | 307,000 | 350,000 | 370,000 | ||
| Circulation Flow Rate | ℓ | 10,000 | 11,850 | 12,040 | 12,500 | 15,000 | 15,350 | 17,500 | 18,500 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | ||||||||
| Head Loss | MPa{mH₂O} | 0.004{0.4} | 0.005{0.5} | 0.005{0.5} | 0.006{0.6} | 0.005{0.5} | 0.005{0.5} | 0.007{0.7} | 0.008{0.8} | |
| Material | - | Stainless Steel Pipe | ||||||||
| Connection Size | A | 50 | 50 | 50 | 50 | 65 | 65 | 65 | 65 | |
Hot Water Supply (298K → 338K) {25℃ → 65℃}
| Category | Type | Unit | KDNV- 20G2MHEX | KDNV- 23G2MHEX | KDNV- 24G2MHEX | KDNV- 25G2MHEX | KDNV- 30G2MHEX | KDNV- 31G2MHEX | KDNV- 35G2MHEX | KDNV- 37G2MHEX |
|---|---|---|---|---|---|---|---|---|---|---|
| Hot Water Supply | Rated Heat Output | MW | 0.23 | 0.28 | 0.28 | 0.29 | 0.35 | 0.36 | 0.41 | 0.43 |
| kcal/h | 200,000 | 237,000 | 240,800 | 250,000 | 300,000 | 307,000 | 350,000 | 370,000 | ||
| Circulation Flow Rate | ℓ | 3,333 | 5,925 | 6,020 | 4,167 | 5,000 | 5,117 | 5,833 | 6,167 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | ||||||||
| Head Loss | MPa{mH₂O} | 0.001{0.1} | 0.001{0.1} | 0.001{0.1} | 0.001{0.1} | 0.001{0.1} | 0.001{0.1} | 0.001{0.1} | 0.001{0.1} | |
| Material | - | Stainless Steel Pipe | ||||||||
| Connection Size | A | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | |
The above specification table is presented as follows.
- The fuel heating values used to calculate fuel consumption are based on the following.
- Fuel: Higher Heating Value_Lower Heating Value
- LNG : 11,000_10,000 kcal/Nm³
- Propane: 24,350_22,400 kcal/Nm³
Design flow temperature condition for heating and hot water circulation: 333~343K{60~70℃}
Design flow temperature condition for hot water supply: 298~338K{25~65℃}, 278~338K{5~65℃}
The rated heat outputs for heating and hot water supply apply when each function is used independently. When used simultaneously, their combined output equals the boiler heat output.
The following tolerances account for measurement errors from instruments and operators.
- Boiler efficiency measurement error: ±1%; fuel quantity (heat input) measurement error: ±1.5%
The boiler efficiency stated above is based on the lower heating value.
The specifications above are subject to change without notice.
STANDARD SPECIFICATIONS
| Category | Type | Unit | KDNV- 40G2MHEX | KDNV- 42G2MHEX | KDNV- 43G2MHEX | KDNV- 45G2MHEX | KDNV- 50G2MHEX | KDNV- 60G2MHEX |
|---|---|---|---|---|---|---|---|---|
| Boiler Specifications | Rated Heat Output | MW | 0.47 | 0.49 | 0.50 | 0.52 | 0.58 | 0.70 |
| kcal/h | 400,000 | 420,000 | 430,000 | 450,000 | 500,000 | 600,000 | ||
| Efficiency | % | 99% or Higher (Based on Lower Heating Value) | ||||||
| Heat Transfer Area | m² | 8.0 | 8.0 | 8.0 | 8.0 | 8.0 | 11.1 | |
| Burner | - | DP5 | ||||||
| Burner Capacity | kcal/h | 140,000 ~ 700,000 | ||||||
| Control Method | - | Inverter Proportional Control | ||||||
| Blower Capacity | kW | 1.8 | ||||||
| Total Power Consumption | kW | 1.9 | ||||||
| Power Supply | V | 220V x 1ø | ||||||
| Product Weight | kg | 1,240 | 1,250 | 1,260 | 1,270 | 1,280 | 1,700 | |
| Fuel Consumption | LNG | N㎥/h | 40.4 | 42.4 | 43.4 | 45.5 | 50.5 | 60.6 |
| Propane (LPG) | N㎥/h | 18.0 | 18.9 | 19.4 | 20.3 | 22.5 | 27.1 | |
| Connection Size | Gas Inlet | A | 40 | |||||
| Flue | ømm | 250 | 250 | 250 | 250 | 300 | 300 | |
| Overall Dimensions | Width (W) | mm | 1,050 | 1,050 | 1,050 | 1,050 | 1,050 | 1,050 |
| Length (L) | 2,900 | 2,900 | 2,900 | 2,900 | 2,960 | 3,430 | ||
| Height (H) | 1,780 | 1,780 | 1,780 | 1,780 | 1,780 | 1,780 | ||
Heating & Hot Water Circulation (333K → 343K) {60℃ → 70℃}
| Category | Type | Unit | KDNV- 40G2MHEX | KDNV- 42G2MHEX | KDNV- 43G2MHEX | KDNV- 45G2MHEX | KDNV- 50G2MHEX | KDNV- 60G2MHEX |
|---|---|---|---|---|---|---|---|---|
| Heating and Hot Water Circulation | Rated Heat Output | MW | 0.47 | 0.49 | 0.50 | 0.52 | 0.58 | 0.70 |
| kcal/h | 400,000 | 420,000 | 430,000 | 450,000 | 500,000 | 600,000 | ||
| Circulation Flow Rate | ℓ | 40,000 | 42,000 | 43,000 | 45,000 | 50,000 | 60,000 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | ||||||
| Head Loss | MPa{mH₂O} | 0.035{3.5} | 0.039{3.9} | 0.041{4.1} | 0.029{2.9} | 0.036{3.6} | 0.052{5.2} | |
| Material | - | Stainless Steel Pipe | ||||||
| Connection Size | A | 65 | 65 | 65 | 80 | 80 | 80 | |
Heating & Hot Water Circulation (333K → 343K) {50℃ → 70℃}
| Category | Type | Unit | KDNV- 40G2MHEX | KDNV- 42G2MHEX | KDNV- 43G2MHEX | KDNV- 45G2MHEX | KDNV- 50G2MHEX | KDNV- 60G2MHEX |
|---|---|---|---|---|---|---|---|---|
| Hot Water Supply | Rated Heat Output | MW | 0.47 | 0.49 | 0.50 | 0.52 | 0.58 | 0.70 |
| kcal/h | 400,000 | 420,000 | 430,000 | 450,000 | 500,000 | 600,000 | ||
| Circulation Flow Rate | ℓ | 20,000 | 21,000 | 21,500 | 22,500 | 25,000 | 30,000 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | ||||||
| Head Loss | MPa{mH₂O} | 0.009{0.9} | 0.01{1.0} | 0.01{1.0} | 0.007{0.7} | 0.009{0.9} | 0.013{1.3} | |
| Material | - | Stainless Steel Pipe | ||||||
| Connection Size | A | 65 | 65 | 65 | 80 | 80 | 80 | |
Hot Water Supply (298K → 338K) {25℃ → 65℃}
| Category | Type | Unit | KDNV- 40G2MHEX | KDNV- 42G2MHEX | KDNV- 43G2MHEX | KDNV- 45G2MHEX | KDNV- 50G2MHEX | KDNV- 60G2MHEX |
|---|---|---|---|---|---|---|---|---|
| Hot Water Supply | Rated Heat Output | MW | 0.47 | 0.49 | 0.50 | 0.52 | 0.58 | 0.70 |
| kcal/h | 400,000 | 420,000 | 430,000 | 450,000 | 500,000 | 600,000 | ||
| Circulation Flow Rate | ℓ | 6,667 | 7,000 | 7,167 | 7,500 | 8,333 | 10,000 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | ||||||
| Head Loss | MPa{mH₂O} | 0.002{0.2} | 0.002{0.2} | 0.002{0.2} | 0.001{0.1} | 0.002{0.2} | 0.002{0.2} | |
| Material | - | Stainless Steel Pipe | ||||||
| Connection Size | A | 50 | 50 | 50 | 65 | 65 | 65 | |
The above specification table is presented as follows.
- The fuel heating values used to calculate fuel consumption are based on the following.
- Fuel: Higher Heating Value_Lower Heating Value
- LNG : 11,000_10,000 kcal/Nm³
- Propane: 24,350_22,400 kcal/Nm³
Design flow temperature condition for heating and hot water circulation: 333~343K{60~70℃}
Design flow temperature condition for hot water supply: 298~338K{25~65℃}, 278~338K{5~65℃}
The rated heat outputs for heating and hot water supply apply when each function is used independently. When used simultaneously, their combined output equals the boiler heat output.
The following tolerances account for measurement errors from instruments and operators.
- Boiler efficiency measurement error: ±1%; fuel quantity (heat input) measurement error: ±1.5%
The boiler efficiency stated above is based on the lower heating value.
The specifications above are subject to change without notice.
STANDARD SPECIFICATIONS
| Category | Type | Unit | KDNV- 70G2MHEX | KDNV- 75G2MHEX | KDNV- 80G2MHEXS | KDNV- 80G2MHEX | KDNV- 100G2MHEX |
|---|---|---|---|---|---|---|---|
| Boiler Specifications | Rated Heat Output | MW | 0.81 | 0.87 | 0.93 | 0.93 | 1.16 |
| kcal/h | 700,000 | 750,000 | 800,000 | 800,000 | 1,000,000 | ||
| Efficiency | % | 99% or Higher (Based on Lower Heating Value) | |||||
| Heat Transfer Area | m² | 11.1 | 11.1 | 11.1 | 16.1 | 17.4 | |
| Burner | - | DP8 | DP10 | ||||
| Burner Capacity | kcal/h | 200,000 ~ 1,000,000 | 250,000 ~ 1,250,000 | ||||
| Control Method | - | Inverter Proportional Control | |||||
| Blower Capacity | kW | 2.9 | 3.6 | ||||
| Total Power Consumption | kW | 3.0 | 3.7 | ||||
| Power Supply | V | 380V x 3ø | |||||
| Product Weight | kg | 1,710 | 1,720 | 1,750 | 1,900 | 2,050 | |
| Fuel Consumption | LNG | N㎥/h | 70.7 | 75.8 | 80.8 | 80.8 | 101.0 |
| Propane (LPG) | N㎥/h | 31.6 | 33.8 | 36.1 | 36.1 | 45.1 | |
| Connection Size | Gas Inlet | A | 50 | 50 | |||
| Flue | ømm | 300 | 300 | 350 | 350 | 350 | |
| Overall Dimensions | Width (W) | mm | 1,050 | 950 | 950 | 1,240 | 1,240 |
| Length (L) | 3,480 | 3,640 | 3,640 | 3,640 | 3,740 | ||
| Height (H) | 1,780 | 1,780 | 1,780 | 1,590 | 1,590 | ||
Heating & Hot Water Circulation (333K → 343K) {60℃ → 70℃}
| Category | Type | Unit | KDNV- 70G2MHEX | KDNV- 75G2MHEX | KDNV- 80G2MHEXS | KDNV- 80G2MHEX | KDNV- 100G2MHEX |
|---|---|---|---|---|---|---|---|
| Heating and Hot Water Circulation | Rated Heat Output | MW | 0.81 | 0.87 | 0.93 | 0.93 | 1.16 |
| kcal/h | 700,000 | 750,000 | 800,000 | 800,000 | 1,000,000 | ||
| Circulation Flow Rate | ℓ | 70,000 | 75,000 | 80,000 | 80,000 | 100,000 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | |||||
| Head Loss | MPa{mH₂O} | 0.045{4.5} | 0.052{5.2} | 0.059{5.9} | 0.059{5.9} | 0.093{9.3} | |
| Material | - | Stainless Steel Pipe | |||||
| Connection Size | A | 100 | 100 | 100 | 100 | 100 | |
Heating & Hot Water Circulation (333K → 343K) {50℃ → 70℃}
| Category | Type | Unit | KDNV- 70G2MHEX | KDNV- 75G2MHEX | KDNV- 80G2MHEXS | KDNV- 80G2MHEX | KDNV- 100G2MHEX |
|---|---|---|---|---|---|---|---|
| Hot Water Supply | Rated Heat Output | MW | 0.81 | 0.87 | 0.93 | 0.93 | 1.16 |
| kcal/h | 700,000 | 750,000 | 800,000 | 800,000 | 1,000,000 | ||
| Circulation Flow Rate | ℓ | 35,000 | 37,500 | 40,000 | 40,000 | 50,000 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | |||||
| Head Loss | MPa{mH₂O} | 0.011{1.1} | 0.013{1.3} | 0.015{1.5} | 0.015{1.5} | 0.023{2.3} | |
| Material | - | Stainless Steel Pipe | |||||
| Connection Size | A | 100 | 100 | 100 | 100 | 100 | |
Hot Water Supply (298K → 338K) {25℃ → 65℃}
| Category | Type | Unit | KDNV- 70G2MHEX | KDNV- 75G2MHEX | KDNV- 80G2MHEXS | KDNV- 80G2MHEX | KDNV- 100G2MHEX |
|---|---|---|---|---|---|---|---|
| Hot Water Supply | Rated Heat Output | MW | 0.81 | 0.87 | 0.93 | 0.93 | 1.16 |
| kcal/h | 700,000 | 750,000 | 800,000 | 800,000 | 1,000,000 | ||
| Circulation Flow Rate | ℓ | 11,667 | 12,500 | 13,333 | 13,333 | 16,667 | |
| Max. Working Pressure | MPa{kgf/cm²} | 1{10} | |||||
| Head Loss | MPa{mH₂O} | 0.002{0.2} | 0.002{0.2} | 0.003{0.3} | 0.003{0.3} | 0.004{0.4} | |
| Material | - | Stainless Steel Pipe | |||||
| Connection Size | A | 80 | 80 | 80 | 80 | 80 | |
The above specification table is presented as follows.
- The fuel heating values used to calculate fuel consumption are based on the following.
- Fuel: Higher Heating Value_Lower Heating Value
- LNG : 11,000_10,000 kcal/Nm³
- Propane: 24,350_22,400 kcal/Nm³
Design flow temperature condition for heating and hot water circulation: 333~343K{60~70℃}
Design flow temperature condition for hot water supply: 298~338K{25~65℃}
The rated heat outputs for heating and hot water supply apply when each function is used independently. When used simultaneously, their combined output equals the boiler heat output.
The following tolerances account for measurement errors from instruments and operators.
- Boiler efficiency measurement error: ±1%; fuel quantity (heat input) measurement error: ±1.5%
The boiler efficiency stated above is based on the lower heating value.
The specifications above are subject to change without notice.
Consultation and quotes
Tell us where the boiler will be installed and what it is for.
Our engineers will get back to you.